Prime

GSH PLAZA is a prestigious commercial and office tower in the heart of Singapore's Central Business District, well-positioned to deliver key advantages to investors looking to capitalise on its strategic location and premium offerings.

As one of the world's most business-friendly places, Singapore is poised to edge out major global cities with its allure as a gateway city, presenting investors with opportunities to ride the region's growth wave and strengthen international presence.

Asia's improved economy has led to an increase in the demand for office space across the region. GSH Plaza will tap onto this favourable demand and link businesses to a multitude of space solutions, and in turn provide investors with a prime platform for investment.

Prime Presence

Prime Position - In the Heart of Central Business District

Prime Place - Connecting You to Any Point

GSH LOCATION MAP

Delivering Greater Yield

Prime Pick - Planned to Compliment Every Need

BASEMENT
BASEMENT
1ST STOREY
1st Storey
2nd STOREY
2nd STOREY
3rd STOREY
3rd STOREY
4th STOREY
4th STOREY
5th-15th STOREY
5th-15th STOREY
16th STOREY
16th STOREY
17th STOREY
17th STOREY
18th STOREY
18th STOREY
19th-25th STOREY
19th-25th STOREY
26th STOREY
26th STOREY
27th STOREY
27th STOREY
28th STOREY
28th STOREY
BASEMENT
1ST STOREY
2nd STOREY
3rd STOREY
4th STOREY
5th-15th STOREY
16th STOREY
17th STOREY
18th STOREY
19th-25th STOREY
26th STOREY
27th STOREY
28th STOREY
VIEW ALL

Basement

Download PDF
close

1st Storey

View Details

1st Storey

Unit No.
Area(m2)
#01-01 (F&B)
43
#01-02 (F&B)
44
#01-03 (F&B)
54
#01-04 (F&B)
65
#01-05 (F&B)
53
#01-06 (F&B)
75
#01-07 (F&B)
37
#01-08 (Retail)
36
Download PDF
close

2nd Storey

View Details

2nd Storey

Unit No.
Area(m2)
#02-01 (F&B)
58
#02-02 (F&B)
39
#02-03 (Retail)
58
#02-04 (Retail)
53
#02-05 (F&B)
76
#02-06 (Retail)
46
#02-07 (Retail)
48
#02-08 (Retail)
46
#02-09 (F&B)
50
#02-10 (Retail)
53
#02-11 (Retail)
58
#02-12 (F&B)
50
#02-13 (F&B)
96
Download PDF
close

3rd Storey

View Details

3rd Storey

Unit No.
Area(m2)
#03-01
54
#03-02
78
#03-03
159
#03-04
119
#03-05
132
#03-06
142
#03-07
132
#03-08
120
#03-09
105
#03-10
94
#03-11
92
#03-12
102
#03-13
107
#03-14
73
Download PDF
close

4th Storey

View Details

4th Storey

Unit No.
Area(m2)
#04-01
54
#04-02
45
#04-03
111
#04-04
99
#04-05
118
#04-06
126
#04-07
118
#04-08
99
#04-09
120
#04-10
70
Download PDF
close

5th - 15th Storey

View Details

5th - 15th Storey

Unit No.
Area(m2)
#05~15-01
58
#05~15-02
48
#05~15-03
115
#05~15-04
99
#05~15-05
118
#05~15-06
126
#05~15-07
118
#05~15-08
102
#05~15-09
124
#05~15-10
73
Download PDF
close

16th Storey

View Details

16th Storey

Unit No.
Area(m2)
#16-01
103
#16-02
115
#16-03
99
#16-04
118
#16-05
126
#16-06
118
#16-07
102
#16-08
123
#16-09
92
Download PDF
close

17th Storey

View Details

17th Storey

Unit No.
Area(m2)
#17-01
153
#17-02
115
#17-03
99
#17-04
118
#17-05
126
#17-06
118
#17-07
102
#17-08
123
Download PDF
close

18th Storey

View Details

18th Storey

Unit No.
Area(m2)
#18-01
93
#18-02
75
#18-03
115
#18-04
99
#18-05
118
#18-06
126
#18-07
118
#18-08
102
#18-09
123
#18-10
73
Download PDF
close

19th - 25th Storey

View Details

19th - 25th Storey

Unit No.
Area(m2)
#19~25-01
93
#19~25-02
75
#19~25-03
115
#19~25-04
99
#19~25-05
118
#19~25-06
126
#19~25-07
118
#19~25-08
102
#19~25-09
123
#19~25-10
73
Download PDF
close

26th Storey

View Details

26th Storey

Unit No.
Area(m2)
#26-01
93
#26-02
75
#26-03
109
#26-04
81
#26-05
107
#26-06
116
#26-07
107
#26-08
84
#26-09
117
#26-10
73
Download PDF
close

27th Storey

View Details

27th Storey

Unit No.
Area(m2)
#27-01
124
#27-02
75
#27-03
107
#27-04
81
#27-05
108
#27-06
117
#27-07
108
#27-08
84
#27-09
118
Download PDF
close

28th Storey

View Details

28th Storey

Unit No.
Area(m2)
#28-01
119
#28-02
71
#28-03
103
#28-04
81
#28-05
108
#28-06
117
#28-07
108
#28-08
81
#28-09
114
Download PDF
close

BUILDING SPECIFICATIONS

  1. STRUCTURE

    Raft foundation with reinforced concrete structure

  2. WALLS
    1. External Walls: Concrete and/or Masonry walls and/or Pre-cast and/or Aluminium & Glazing Wall cladding
    2. Internal Walls: Concrete and/or masonry and/or partition wall
  3. ROOF

    Reinforced concrete flat roof with waterproofing system with or without insulation

  4. CEILING

    All ceiling with skim coat unless otherwise stated. Ceiling board with painted finishes to corridors, main lobby and lift lobby.

  5. FINISHES
    1. Wall: Masonry and/or dry partition wall plastered and paint. Imported tiles to washroom, lift lobby and corridors. Plastered and paint to basement wall.
    2. Floor: Cement rendered finishes to all units unless otherwise stated. Imported tiles to washroom, lift lobby and corridors. Epoxy paint finish to basement carpark and driveway.
  6. WINDOWS

    Office Unit:
    Window and/or Casement Window with Aluminum frame (where applicable) Double Glazed glass and/or Double Glazed Safety glass (where applicable)

  7. DOORS

    Office Unit:
    Glass and/or timber doors and PSB's approved fire-rated doors where applicable.

    Shop, Restaurant Unit:
    Glass door

  8. IRONMONGERY

    Office, Shop, Restaurant Unit:
    Imported good quality ironmongery

  9. SANITARY FITTINGS (CHANGE TO SANITARY AND PLUMBING IF REQUIRED)

    Office Unit:
    Imported good quality sanitary wares, fittings and accessories (To applicable units only)

  10. ELECTRICAL INSTALLATION

    415V three phase isolator for shop, restaurant and office units.

  11. GAS SYSTEM

    Restaurant Unit:
    Town gas supply

  12. AIR-CONDITIONING SYSTEM AND MECHANICAL VENTILATION

    Individual Air-conditioning system provided for shop, restaurant and office units.

    Air-conditioning system provided to all lobbies and corridors. Mechanical Ventilation will be provided if required.

  13. LIFTS

    Lift to all floors

  14. TELECOMMUNICATION SERVICES

    Provision of Cable network

    Each unit will be provided with the telephone block terminal

  15. LIGHTNING PROTECTION

    Lightning Protection System shall be provided in accordance with Singapore Standard 555: 2010

  16. WATERPROOFING

    Office Unit:
    Waterproofing to unit washrooms

    Shop, Restaurant Unit: Nil

    Common Areas:
    Waterproofing to common Toilets, Pantry, Bin Centre and Reinforced Concrete Roof

  17. DRIVEWAY

    Stone paving to designated 1st Storey areas of driveway

  18. SECURITY SYSTEM

    Card Access control system to selected locations
    Proximity transponder for vehicular entry at entrances
    CCTV, surveillance cameras at strategic locations

  19. FLOOR LOADING

    The maximum allowable floor loading for Shops/ Restaurant Units and Office Units are as follows:

    1. Restaurant Unit/Shop (1st and 2nd Storey) - 5.0kN/m2
    2. Office Unit (3rd to 28th Storey) - 4.0kN/m2

DISCLAIMER:
While reasonable care has been taken in preparing the sales brochure, unit plans, specifications, constructing the sales models, sales gallery and marketing collaterals (the 'Materials'), the Developer and its agents and their respective servants and contractors do not warrant the accuracy of any of the Materials and shall be in no way be held responsible for any inaccuracies in their contents or discrepancies between the Materials and the actual project and/or units when built. The Developer shall not be bound by any statement, representation or promise (written or oral) by its agent or contractors. All statements and depictations are believed to be correct but are not to be regarded as statements or representations of fact. The Sale and Purchase Agreement shall form the entire agreement between the Developer and the Purchaser and shall supersede all statements, representations or promises made prior to the signing of the Sale and Purchase Agreement. All information, specifications, layout plans, building plans, location of facilities, finishes and visuals are subject to any changes as may be required by the Architect or Developer and/or approved by the relevant authorities. The Materials are not intended to be contractual documents and shall not form part of any offer or contract. Visuals, renderings, illustrations, models, displays and photography are artist's impressions only and it shall not be regarded as representation of fact. Floor areas are approximate measurements only and it is subject to final survey verification. The property is subject to inspection by the relevant authorities to comply with the current codes of practice.

DEVELOPED BY